RUNBOOK FOR APRIL 2012 HILUM BEAM RUN ===================================== ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Run #| Date |Run |Run |Evts |Quality|HV_FCAL|HV_FCAL|HV_EMEC|HV_HEC|HV Cher| Position |Intensity from| S4 | S123 |Ionisation| Comments | |start|stop | | |250[kV]|100[kV]| [kV] | [kV] | [kV] |HEC EMEC FCal| Cerenkov | | | chamber | | |time |time | | | | | | | | | | | | | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 851 |09.4.2012|12:00|12:10|10000| good | 0.000| 0.000| 0.0 | 0.0 | 0.0 |70.1 63.3 19.0| 2e11 | | | | template ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Shift crew: Kozelov, Kuhtin, Merkulov, Savin Attenuator set: 30 854 |09.04.2012|20:40|20:47| ? |tuning| 0.000| 0.000| 0.0 | 0.0 | 0.0 |center - - | 2e11 | | | 1.1e11 | first run in 2012 deleted: runs at 450 rvts/spill! #samples was set to calibration = 64 9996 630 630 855 |09.04.2012|22:35|22:47|10000|tuning| 0 | 0 | 0 | 1200 | 1.07 |center - - | 2e11 | | | | 1st usable,HEC in 857 |10.04.2012|00:07|00:22|10000|tuning| 0 | 0 | 0 | 1200 | 1.07 |center - - | 2e11 | | | | repeating 855 Ch corrected 858 |10.04.2012|05:25|05:31| 5000| test | 0 | 0 | 0 | 1200 | 1.07 |center - - | 2e11 | | | | testing SOB/EOB ... 16:00 Shift crew: Kozelov, Maslennikov, Schacht Calibrating Cherenkov at low intensity 860 |10.04.2012|18:22|18: |10000| test | 0 | 0 | 0 | 0 | 2.55 |center - - | 2.7e6 | | | | Cherenkov pressure 1 atm 861 |10.04.2012|18:22|18:57|10000| test | 0 | 0 | 0 | 0 | 2.50 |center - - | 2.7e6 | | | | Cherenkov pressure 1 atm 862 |10.04.2012|19:00|19:16|10000| test | 0 | 0 | 0 | 0 | 2.45 |center - - | 2.7e6 | | | | Cherenkov pressure 1 atm 863 |10.04.2012|19:20|19:35|10000| test | 0 | 0 | 0 | 0 | 2.40 |center - - | 2.7e6 | | | | Cherenkov pressure 1 atm 864 |10.04.2012|19:39|19:54|10000| test | 0 | 0 | 0 | 0 | 2.35 |center - - | 2.7e6 | | | | Cherenkov pressure 1 atm 865 |10.04.2012|19:57|20:13|10000| test | 0 | 0 | 0 | 0 | 2.30 |center - - | 2.7e6 | | | | Cherenkov pressure 1 atm 866 |10.04.2012|20:16|20:31|10000| test | 0 | 0 | 0 | 0 | 2.25 |center - - | 2.7e6 | | | | Cherenkov pressure 1 atm Finished Cherenkov HV scan, starting a pressure scan 867 |10.04.2012|20:36|20:51|10000| test | 0 | 0 | 0 | 0 | 2.55 |center - - | 2.7e6 | | | | Cherenkov pressure 0.65 atm 868 |10.04.2012|20:55|21:10|10000| test | 0 | 0 | 0 | 0 | 2.55 |center - - | 2.7e6 | | | | Cherenkov pressure 0.70 atm 869 |10.04.2012|21:14|21:29|10000| test | 0 | 0 | 0 | 0 | 2.55 |center - - | 2.7e6 | | | | Cherenkov pressure 0.75 atm 870 |10.04.2012|21:33|21:48|10000| test | 0 | 0 | 0 | 0 | 2.55 |center - - | 2.7e6 | | | | Cherenkov pressure 0.80 atm 871 |10.04.2012|21:52|22:07|10000| test | 0 | 0 | 0 | 0 | 2.55 |center - - | 2.7e6 | | | | Cherenkov pressure 0.85 atm beam data have not arrived for some spills During copying the run 871, the vme computer has got stuck. After rebooting procedure (see the logbook), repeat the run 872 |10.04.2012|22:45|23:05|10000| test | 0 | 0 | 0 | 0 | 2.55 |center - - | 2.7e6 | | | | Cherenkov pressure 0.85 atm (repeat run 871) 873 |10.04.2012|23:09|23:14| 3157| test | 0 | 0 | 0 | 0 | 2.55 |center - - | 2.7e6 | | | | Cherenkov pressure 0.90 atm no beam, accelerator problem 874 |11.04.2012|00:15|00:30|10000| test | 0 | 0 | 0 | 0 | 2.55 |center - - | 1.6e6 | | | | Cherenkov presssure 0.90 atm 875 |11.04.2012|00:44|00:59|10100| test | 0 | 0 | 0 | 0 | 2.55 |center - - | 1.7e6 | | | | Cherenkov pressure 0.95 atm Some missing EOS blocks 876 |11.04.2012|01:03|18:58|10100| test | 0 | 0 | 0 | 0 | 2.55 |center - - | 2.0e6 | | | | Cherenkov pressure 1.00 atm Finished Cherenkov pressure scan. Start "albedo" study to see how many shower particles in absorber scatter back into trigger counters. Start with 4 absorber plates FCAL250 alignment completed 898 failed 899 faile 877 |11.04.2012|01:45|02:00|10100| test | 0 | 0 | 0 | 0 | 2.55 |center - - | 2.0e6 | | | | Cherenkov pressure 1.00 atm from here on 878 |11.04.2012|02:18|02:34|10100| test | 0 | 0 | 0 | 0 | 2.55 |center - - | 2.0e6 | | | | Added 4 Iron plates. Now 8. 879 |11.04.2012|02:55|03:10|10100| test | 0 | 0 | 0 | 0 | 2.55 |center - - | 2.1ebunches-20126 | | | Added poly plate upstream of the 8 Iron plates Finished albedo study. Absorbers now removed. Turned on HV to HEC Prepare to center HEC on nominal beam. We increased the beam intensity. 880 |11.04.2012|04:36|04:51|10100| test | 0 | 0 | 0 | 1000 | 1.90 |9996 - - | 4.0e7 | | | 1.2e08 | Start to center the HEC 881 |11.04.2012|05:01|05:16|10100| test | 0 | 0 | 0 | 1000 | 1.90 | 0 - - | 6.1e7 | | | 1.1e08 | Move HEC out 2 mm 882 |11.04.2012|05:26|05:41|10100| test | 0 | 0 | 0 | 1000 | 2.38 | 4 - - | 3.8e7 | | | 9.3e7 | Moved HEC out another 2 mm 883 |11.04.2012|05:48|06:03|10100| test | 0 | 0 | 0 | 1000 | 2.38 | 12 - - | 4.5e7 | | | 9.6e7 | Moved HEC out 4 mm 884 |11.04.2012|06:09|06:24|10100| test | 0 | 0 | 0 | 1000 | 2.38 | 20 - - | 5.1e7 | | | 9.0e7 | Moved HEC out another 4 mm 885 |11.04.2012|06:33|06:48|10100| test | 0 | 0 | 0 | 1000 | 2.38 | 19 - - | 4.3e7 | | | 1.1e8 | Too far. Try 19. Prepare to center the EMEC starting from a reasonably centered position. FCAL250 alignment completed 898 failed 899 faile 886 |11.04.2012|07:36|07:51|10100| test | 0 | 0 | 1000 | 1000 | 2.38 | 19 0 - | 4.3e7 | | | 1.4e8 | Moved EMEC into beam 11.04.2012 09:19 Attenuation for the module signals was introduced as 1:1 by A,Savin 887 |11.04.2012| | | | test | 0 | 0 | 1000 | 1000 | | 19 xx - | | | | | 888 |11.04.2012|09:36| | | test | 0 | 0 | 1000 | 1200 | | 19 00 - | 3.9e+7 | | | 1.0e+8 | Aligning EMEC 889 |11.04.2012|10:11| | | test | 0 | 0 | 1000 | 1200 | | 19 10 | 4.5e+7 | 1.0e+8 EMEC alignment 890 |11.04.2012|10:40| | | test | 0 | 0 | 1000 | 1200 | | 17 10 21| 2.7e7 | 1.0e+8 HEC and EMEC verification 891 |11.04.2012|11:07| | | test | 250 | 0 | 1000 | 1200 | | 17 10 21| 892 |11.04.2012|11:20| | | test | 250 | 0 | 1000 | 1000 | | 17 10 25| 5.0e+7 | FCAL250 alignment 893 |11.04.2012|11:39| | | test | 250 | 0 | 1000 | 1000 | | 17 10 19| 3.9e+7 | = / = 894 |11.04.2012|11:55| | | test | 250 | 0 | 1000 | 1000 | | 17 10 23| | = / = 895 |11.04.2012|11: | | | test | 250 | 0 | 1000 | 1000 | | 17 10 40| | 896 |11.04.2012|11:32| | | test | 250 | 0 | 1000 | 1000 | | 17 10 35| 4.7e+7 | | | 1/0e+08 | 897 |11.04.2012| | | | test | 250 | 0 | 1000 | 1000 | | 17 10 45| | | 898 |11.04.2012| | | | | | | | | | | | failed 899 |11.04.2012| | | | | | | | | | | | failed 900 |11.04.2012|13 | | | test | 250 | 0 | 1000 | 1000 | | 17 10 35| 1.0e+6 | Vertical scan Y=8.2 901 |11.04.2012|14:05| | | test | 250 | 0 | 1000 | 1000 | | 17 10 35| 1.0e+06 | Y=7.4 11.04.2012 14:50 Attenuation for the module signals was introduced as 1:30 by A,Savin 902 |11.04.2012|15:25| | | test | 250 | 0 | 1000 | 1000 | 1.05 | 17 10 35| 2.3e+11 | | | | 903 |11.04.2012| | | | test | 250 | 0 | 1000 | 1000 | 1.05 | 17 10 35| 3.5e+11 | | | | 904 |11.04.2012| | | | test | 250 | 0 | 1000 | 1000 | 1.05 | 17 10 35| 2.1e+11 | | | | 905 |11.04.2012|18:32| | | test | 250 | 0 | 1200 | 1200 | 1.05 | 17 10 35| 2.1e+11 | | | 1.1e+11 | check beam profile 906 |11.04.2012|19:21| | | test | 250 | 0 | 800 | 800 | 1.05 | 17 10 35| 1.7e+11 | | | | check beam profile 907 |11.04.2012|20:50| | | test | 250 | 0 | 1200 | 1200 | 1.05 | 17 10 35| 1.8e+11 | | | | check EMEC signals 11.04.2012 start HV scan, attenuators still 1:30 ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Run #| Date |Run |Run |Evts | Qua |HV_FCAL|HV_FCAL|HV_EMEC|HV_HEC|HV Cher| Position |Intensity from| S4 | S123 |Ionisation| Comments | |start|stop | | lity |250[kV]|100[kV]| [kV] | [kV] | [kV] |HEC EMEC FCal| Cerenkov | | | chamber | | |time |time | | | | | | | | | | | | | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 908 |11.04.2012|20:57| | | Scan | 250 | 0 | 1200 | 1200 | 1.05 | 17 10 35| 1.3e+11 | | | 1e+11 | HV scan. first 20% at 1.8e+11 909 |11.04.2012|21:16| | | Scan | 160 | 0 | 800 | 800 | 1.05 | 17 10 35| 1.2e+11 | | | 1e+11 | 910 |11.04.2012|21:39| | | Scan | 60 | 0 | 600 | 600 | 1.06 | 17 10 35| 1.2e+11 | | | 1e+11 | 912 |11.04.2012|22:01| | | Scan | 0 | 0 | 0 | 0 | 1.06 | 17 10 35| 1.2e+11 | | | 1e+11 | 913 |11.04.2012| | | | test | 0 | 40 | 500 | 500 | 1.06 | 17 10 9987| 1.2e+11 | | | | checl beam position, contamination of 'empty bunches' 914 |12.04.2012|00:10| | 2000| test | 0 | 40 | 500 | 500 | 1.06 | 17 10 9987| 1.2e+11 | | | 1e+11 | 915 |12.04.2012|00:25| |10000| Scan | 0 | 40 | 500 | 500 | 1.06 | 17 10 9987| 1.2e+11 | | | 1e+11 | HV scan, HEC, EMEC, FCAL100 916 |12.04.2012|00:51| | ?| Short| 0 | 60 | 700 | 700 | 1.06 | 17 10 9987| 1.2e+11 | | | 1e+11 | short run, DAQ crashed after run, core dump 917 |12.04.2012|01:05| |10000| Scan | 0 | 60 | 700 | 700 | 1.06 | 17 10 9987| 1.2e+11 | | | 1e+11 | OnlineMon: 1 Train events 918 |12.04.2012|01:26| |10000| Scan | 0 | 100 | 1000 |1000 | 1.06 | 17 10 9987| 1.2e+11 | | | 1e+11 | Owerflow in FCAL100 A1, A2, A3, 4 train events 12. 04. 2012 01:49 Set new intensity 5.0e+10, attenuators still 1:30 919 |12.04.2012|02:26|02:40|10000| Scan | 0 | 100 | 1000 |1000 | 1.10 | 17 10 9987| 5.0e+10 | | | 5e+10 | HV scan, intensity from 4.3 upto 5.5e10 920 |12.04.2012|02:45|02:59|10000| Scan | 0 | 60 | 700 | 700 | 1.10 | 17 10 9987| 4.5e+10 | | | 5e+10 | intensity from 4.0 upto 5.0e10 921 |12.04.2012|03:06|03:20|10000| Scan | 0 | 40 | 500 | 500 | 1.10 | 17 10 9987| 4.5e+10 | | | 5e+10 | 922 |12.04.2012|03:28|03:42|10000| Scan | 0 | 0 | 0 | 0 | 1.10 | 17 10 9987| 5.0e+10 | | | 5e+10 | 923 |12.04.2012|03:54|04:09|10000| Scan | 60 | 0 | 600 | 600 | 1.10 | 17 10 35| 5.0e+10 | | | 5e+10 | HV scan, FCAL250 in beam 924 |12.04.2012|04:15|04:29|10000| Scan | 160 | 0 | 800 | 800 | 1.10 | 17 10 35| 5.0e+10 | | | 5e+10 | FCAL250 in beam 925 |12.04.2012|04:38|04:53|10000| Scan | 250 | 0 | 1200 |1200 | 1.10 | 17 10 35| 5.0e+10 | | | 5e+10 | FCAL250 in beam 12. 04. 2012 05:10 Set new intensity 2.2e+10, attenuators still 1:30 926 |12.04.2012|05:11|05:25|10000| Scan | 250 | 0 | 1200 |1200 | 1.16 | 17 10 35| 2.2e+10 | | | 2e+10 | HV scan, FCAL250 in beam 927 |12.04.2012|05:34|05:48|10000| Scan | 160 | 0 | 800 | 800 | 1.16 | 17 10 35| 2.2e+10 | | | 2e+10 | HV scan, FCAL250 in beam 928 |12.04.2012|05:55|06:10|10000| Scan | 60 | 0 | 600 | 600 | 1.16 | 17 10 35| 2.2e+10 | | | 2e+10 | HV scan, FCAL250 in beam 929 |12.04.2012|06:16|06:30|10000| Scan | 0 | 0 | 0 | 0 | 1.16 | 17 10 35| 2.2e+10 | | | 2e+10 | HV scan, FCAL250 in beam 930 |12.04.2012|06:36|06:51|10000| Scan | 0 | 40 | 500 | 500 | 1.16 | 17 10 9987| 2.2e+10 | | | 2e+10 | HV scan, FCAL100 in beam 931 |12.04.2012|06:56|07:10|10000| Scan | 0 | 60 | 700 | 700 | 1.16 | 17 10 9987| 2.2e+10 | | | 2e+10 | HV scan, FCAL100 in beam 932 |12.04.2012|07:16|07:31|10000| Scan | 0 | 100 | 1000 |1000 | 1.16 | 17 10 9987| 2.2e+10 | | | 2e+10 | HV scan, FCAL100 in beam 12. 04. 2012 07:50 Set new intensity 1.0e+10, new attenuators 1:10 933 |12.04.2012|08:19|08: |10000| Scan | 0 | 100 | 1000 |1000 | 1.16 | 17 10 9987| 1.0e+10 | | | 1e+10 | HV scan, FCAL100 in beam HV_cher was adjusted perhaps at the end ofth e 934 |12.04.2012|08:45| |10000| one | 0 | 100 | 1000 |1000 | 1.26 | 17 10 9987| 1.0e+10 | | | 8e+09 | the same run as 933 935 |12.04.2012|09:37| |10000| one | 250 | 0 | 1200 |1200 | 1.26 | 17 10 35| 1.0e+10 | | | | FCAL250 is in the beam 12. 04. 2012 09:55 Set new intensity 5.0e+09, new attenuators 1:10 936 |12.04.2012| | |10000| one | 250 | 0 | 1200 |1200 | 1.35 | 17 10 35| 5.0e+09 | | | 5e+09 | FCAL250 at lower intensity 937 |12.04.2012|10:34| |10000| one | 0 | 100 | 800 | 800 | 1.35 | 17 10 9987 | 5.0e+09 | | | 5.0e+09 | FCAL100 at lower intensity 12. 04. 2012 12:30 Set new intensity 2.0e+09, new attenuators 1:3 938 |12.04.2012|13:01| |10000| One | 0 | 100 | 800 | 800 | 1.485| 17 10 9987 | 2.0e+09 | | | 1.4e+09 | FCAL100 in the beam (may be corrupted) 940 |12.04.2012|14:43| |10000| One | 0 | 100 | 800 | 800 | 1.485| 17 10 9987 | 2.0e+09 | | | 1.4e+09 | FCAL100 in the beam should be OK 941 |12.04.2012|15:11|15:31|10000| One | 250 | 0 | 1200 | 1200 | 1.485| 17 10 35 | 2.0e+09 | | | 1.4e+09 | FCAL250 in the beam 12. 04. 2012 16:00 Set new intensity 1.0e+09, attenuators still 1:3 942 |12.04.2012|16:05|16:21|10000| One | 250 | 0 | 1200 | 1200 | 1.530| 17 10 35 | 1.1e+09 | | | 2.2e+09 | FCAL250 in the beam 943 |12.04.2012|16:28|1645 |10000| One | 0 | 100 | 800 | 800 | 1.530| 17 10 9987 | 1.0e+09 | | | 1.7e+09 | FCAL100 in the beam 12. 04. 2012 16:00 Set new intensity 5.0e+08, attenuators out! 944 |12.04.2012|17:47|18:01|10000| One | 0 | 100 | 800 | 800 | 1.66 | 17 10 9987 | 5.5e+08 | | | 1.6e+09 | FCAL100 in the beam 945 |12.04.2012|18:25|18:39|10000| One | 250 | 0 | 1200 | 1200 | 1.66 | 17 10 35 | 4.5e+08 | | | 9.5e+08 | FCAL250 in the beam 12. 04. 2012 18:40 Set new intensity 2.0e+08, attenuators out! 946 |12.04.2012|22:02|22:16|10000| One | 250 | 0 | 1200 | 1200 | 1.72 | 17 10 35 | 2.3e+08 | | | 4.2e+08 | FCAL250 in the beam, too many empty events! 947 |12.04.2012|22:21|22:38|10000| One | 0 | 100 | 800 | 800 | 1.72 | 17 10 9987 | 2.3e+08 | | | 4.2e+08 | FCAL100 in the beam, 37.6% of events empty! 948 |12.04.2012|22:43|22:59|10000| One | 0 | 100 | 800 | 800 | 1.72 | 17 10 9987 | 2.3e+08 | | | 4.2e+08 | FCAL100 in the beam, repeat run 949 |12.04.2012|23:03|23:17|10000| One | 250 | 0 | 1200 | 1200 | 1.72 | 17 10 35 | 2.3e+08 | | | 4.2e+08 | FCAL250 in the beam, repeat run 12. 04. 2012 23:17 Set new intensity 1.0e+08, attenuators out! 950 |12.04.2012|23:26|22:41|10000| One | 250 | 0 | 1200 | 1200 | 1.75 | 17 10 35 | 8.5e+07 | | | 2.0e+08 | FCAL250 in the beam,64% empty events! 951 |12.04.2012|23:45|23:59|10000| One | 250 | 0 | 1200 | 1200 | 1.75 | 17 10 35 | 8.5e+07 | | | 2.0e+08 | FCAL250 in the beam, repeat .... 952 |13.04.2012|00:07|00:23|10000| One | 0 | 100 | 800 | 800 | 1.75 | 17 10 9987 | 8.5e+07 | | | 2.0e+08 | FCAL100 in the beam, 64% empty events! 953 |13.04.2012|00:28|00:55|10000| One | 0 | 100 | 800 | 800 | 1.75 | 17 10 9987 | 5e+07 | | | 2,0e+08 | FCAL100 in the beam, 954 |13.04.2012|01:01|01:15|10000| One | 250 | 0 | 1200 | 1200 | 1.85 | 17 10 35 | 8.5e+07 | | | 2.0e+08 | FCAL250 in the beam, intensity from 2 to 9e+07, 64% empty events! 955 |13.04.2012|01:22|01:36|10000| One | 250 | 0 | 1200 | 1200 | 1.85 | 17 10 35 | 8.5e+07 | | | 2.0e+08 | FCAL250 in the beam, repeat run, 64% empty events! 956 |13.04.2012|01:43|02:00|10000| One | 250 | 0 | 1200 | 1200 | 1.85 | 17 10 35 | 8.5e+07 | | | 2.0e+08 | FCAL250 in the beam, repeat run 957 |13.04.2012|02:01|02:15|10000| Scan | 250 | 0 | 1200 | 1200 | 1.80 | 17 10 35 | 1e+08 | | | 2.0e+08 | FCAL250 in the beam, HV scan, 64% empty events! 958 |13.04.2012|02:24|02:38|10000| Scan | 250 | 0 | 1200 | 1200 | 1.80 | 17 10 35 | 1e+08 | | | 2.0e+08 | FCAL250 in the beam, HV scan, repeat run 959 |13.04.2012|03:36|03:51|10000| Scan | 160 | 0 | 800 | 800 | 1.80 | 17 10 35 | 1e+08 | | | 2.0e+08 | FCAL250 in the beam, HV scan, 64% empty events!, large intensity variation from 4 to 20e+07 960 |13.04.2012|03:57|04:11|10000| Scan | 160 | 0 | 800 | 800 | 1.80 | 17 10 35 | 1e+08 | | | 2.0e+08 | FCAL250 in the beam, HV scan, repeat run 961 |13.04.2012|04:17|04:31|10000| Scan | 60 | 0 | 600 | 600 | 1.80 | 17 10 35 | 1e+08 | | | 2.0e+08 | FCAL250 in the beam, HV scan, 68% empty events!, large intensity variation from 4 to 20e+07 962 |13.04.2012|04:36|04:11|10000| Scan | 60 | 0 | 600 | 600 | 1.80 | 17 10 35 | 1e+08 | | | 2.0e+08 | FCAL250 in the beam, HV scan, repeat run 963 |13.04.2012|05:07|05:11|10000| Scan | 0 | 0 | 0 | 0 | 1.80 | 17 10 35 | 1e+08 | | | 2.0e+08 | FCAL250 in the beam, HV scan, 0 events per spill, run was aborted 964 |13.04.2012|05:24|05:39|10000| Scan | 0 | 0 | 0 | 0 | 1.80 | 17 10 35 | 1e+08 | | | 2.0e+08 | FCAL250 in the beam, HV scan 13. 04. 2012 05:50 Set new intensity 2.0e+08, attenuators out! 965 |13.04.2012|05:45|04:11|10000| One | 0 | 0 | 0 | 0 | 1.67 | 17 10 35 | 2e+08 | | | 2.0e+08 | Bad run!!! Aborted! 966 |13.04.2012|05:52|06:06|10000| One | 250 | 0 | 1200 | 1200 | 1.67 | 17 10 35 | 2.6e+08 | | | 7.0e+08 | FCAL250 in the beam, 48% empty events! 967 |13.04.2012|06:12|06:25|10000| One | 250 | 0 | 1200 | 1200 | 1.67 | 17 10 35 | 2.6e+08 | | | 7.0e+08 | FCAL250 in the beam, repeat run 13. 04. 2012 06:38 Set new intensity 6.0e+08, attenuators out! 968 |13.04.2012|06:38|06:52|10000| Mini | 250 | 0 | 1200 | 1200 | 1.60 | 17 10 35 | 7.e+08 | | | 1.5e+09 | FCAL250 in the beam, Mini HV scan, 43% empty events! 969 |13.04.2012|06:58|07:12|10000| Mini | 250 | 0 | 1200 | 1200 | 1.60 | 17 10 35 | 7.e+08 | | | 1.5e+09 | FCAL250 in the beam, Mini HV scan, repeat run, intensity periodically jumped upto 2e+09 970 |13.04.2012|07:17|07:31|10000| Mini | 250 | 0 | 1200 | 1200 | 1.60 | 17 10 35 | 5.e+08 | | | 1.e+09 | FCAL250 in the beam, Mini HV scan, repeat run 971 |13.04.2012|07:38|07:31|10000| Mini | 60 | 0 | 600 | 600 | 1.60 | 17 10 35 | 5.e+08 | | | 1.e+09 | FCAL250 in the beam, Mini HV scan 972 |13.04.2012|07:56|08:10|10000| Mini | 60 | 0 | 600 | 600 | 1.60 | 17 10 35 | 5.e+08 | | | 1.e+09 | FCAL250 in the beam, Mini HV scan ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Run #| Date |Run |Run |Evts | Qua |HV_FCAL|HV_FCAL|HV_EMEC|HV_HEC|HV Cher| Position |Intensity from| S4 | S123 |Ionisation| Comments | |start|stop | | lity |250[kV]|100[kV]| [kV] | [kV] | [kV] |HEC EMEC FCal| Cerenkov | | | chamber | | |time |time | | | | | | | | | | | | | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 2012.04.13 08:40 Set new intensity 1.0e09, Savin exchanged attenuators. Was 1:1, now 1:3 973 |13.04.2012|12:35|12:49|10000| Full | 250 | 0 | 1200 | 1200 | | 17 10 35 | 1.3e+09 | | | 0.6e+09 | FCAL250 in beam, Full HV scan EMEC 974 |13.04.2012|13:00|13:15|10000| Full | 160 | 0 | 800 | 800 | | 17 10 35 | 1.15e+09 | | | 0.6e+09 | FCAL250 in beam, Full HV scan EMEC att. bad 975 |13.04.2012|13:31|13:46|10000| Full | 60 | 0 | 600 | 600 | 1.50 | 17 10 35 | 0.9e+09 | | | 0.5e+09 | FCAL250 in beam, Full HV scan EMEC att. bad 976 |13.04.2012|13:56|14:11|10000| Full | 0 | 0 | 0 | 0 | 1.50 | 17 10 35 | 1.2e+09 | | | 0.6e+09 | FCAL250 in beam, Full HV scan EMEC att. bad 977 |13.04.2012|14:23|14:38|10000| Mini | 60 | 0 | 600 | 600 | 1.48 | 17 10 35 | 2.0e+09 | | | 1.0e+09 | FCAL250 in beam, Mini HV scan EMEC att. bad 978 |13.04.2012|14:51|15:05|10000| Mini | 250 | 0 | 1200 | 1200 | 1.48 | 17 10 35 | 2.0e+09 | | | 1.0e+09 | FCAL250 in beam, Mini HV scan - Many failed EOS xfers 2012.04.13 15:30 Set new intensity 5.0e+09, A.Savin exchanged attenuators. Was 1:3, now 1:10 979 |13.04.2012|15:43|15:57|10000| Mini | 250 | 0 | 1200 | 1200 | 1.30 | 17 10 35 | 5.0e+09 | | | 3.2e+09 | FCAL250 in beam, Mini HV scan EMEC att. bad 980 |13.04.2012|16:06|16:20|10000| Mini | 60 | 0 | 600 | 600 | 1.30 | 17 10 35 | 4.9e+09 | | | 7.5e+09 | FCAL250 in beam, Mini HV scan EMEC att. bad 2012.04.13 16:25 Set new intensity 1.0e+10 981 |13.04.2012|16:29|16:43|10000| One | 250 | 0 | 1200 | 1200 | 1.24 | 17 10 35 | 1.1e+10 | | | 6.1e+09 | FCAL250 in beam, One HV scan EMEC att. bad 2012.04.13 16:25 Set new intensity 2.0e+10, L.Kurchaninov has replaced attenuator 1:10 by 1:30 (a good one!) 983 |13.04.2012|18:54|19:10|10000| Full | 250 | 0 | 1200 | 1200 | 1.17 | 17 10 35 | 1.8e+10 | | | 9.8e+09 | FCAL250 in beam, Full HV scan 984 |13.04.2012|19:19|19:33|10000| Full | 160 | 0 | 800 | 800 | 1.17 | 17 10 35 | 1.7e+10 | | | 2.8e+09 | FCAL250 in beam, Full HV scan 985 |13.04.2012|19:39|19:53|10000| Full | 60 | 0 | 600 | 600 | 1.17 | 17 10 35 | 1.6e+10 | | | 6.4e+09 | FCAL250 in beam, Full HV scan 986 |13.04.2012|20:03|20:17|10000| Full | 0 | 0 | 0 | 0 | 1.17 | 17 10 35 | 2.1e+10 | | | 5.2e+09 | FCAL250 in beam, Full HV scan 2012.04.13 20:25 Set new intensity 5.0e+10, 987 |13.04.2012|20:26|20:40|10000| Mini | 60 | 0 | 600 | 600 | 1.10 | 17 10 35 | 4.4e+10 | | | 2.5e+10 | FCAL250 in beam, Mini HV scan 988 |13.04.2012|20:50|21:00|10000| bad | 250 | 0 | 1200 | 1200 | 1.10 | 17 10 35 | 5.0e+10 | | | 3.7e+10 | run stopped because of HV trip (EMEC ch.0) 989 |13.04.2012|21:02|21:16|10000| bad | 250 | 0 | 1200 | 1200 | 1.10 | 17 10 35 | 5.5e+10 | | | 3.1e+10 | bad EMEC CH2 2012.04.13 21:30 Set new intensity 1.0e+11, L.Kurchaninov has replaced the broken attenuator (see logbook about calibration) 990 |13.04.2012|21:49|22:03|10000| One | 250 | 0 | 1200 | 1200 | 1.05 | 17 10 35 | 1.1e+11 | | | 3.7e+10 | FCAL250 in beam, One HV scan. 2012.04.13 22:05 Setting intensity back to 5.0e+10 to complete the Mini HV scan, 991 |13.04.2012|22:09|22:23|10000| Mini | 250 | 0 | 1200 | 1200 | 1.10 | 17 10 35 | 5.5e+10 | | | 2.8e+10 | FCAL250 in beam, Mini HV scan (completing I=5e+10). 2012.04.13 22:10 Setting new intensity 2.0e+11, 992 |13.04.2012|22:31|22:45|10000| bad | 250 | 0 | 1200 | 1200 | 1.05 | 17 10 35 | 1.9e+11 | | | 1.2e+11 | FCAL250 in beam, Full HV scan (wrong gate parameters) 993 |13.04.2012|23: |23: |10000| bad | 250 | 0 | 1200 | 1200 | 1.05 | 17 10 35 | 1.9e+11 | | | 1.2e+11 | re-do as data are not readable (by ROOT) have to tune gate delay and width 994 |13.04.2012|23: |23: |10000| test | 250 | 0 | 1200 | 1200 | 1.05 | 17 10 35 | 1.9e+11 | | | 1.2e+11 | short run to check the fix - all OK 995 |13.04.2012|23: |23:38|10000| bad | 250 | 0 | 1200 | 1200 | 1.07 | 17 10 35 | 2.0e+11 | | | 1.2e+11 | HV trip in HEC ch.2 996 |13.04.2012|23:56|00:10|10000| Full | 250 | 0 | 1200 | 1200 | 1.07 | 17 10 35 | 2.0e+11 | | | 1.1e+11 | FCAL250 in beam, Full HV scan, EMEC bad 997 |14.04.2012|00:18|00:40|10000| Full | 160 | 0 | 800 | 800 | 1.07 | 17 10 35 | 2.0e+11 | | | 1.1e+11 | FCAL250 in beam, Full HV scan, EMEC bad 998 |14.04.2012|00:50|01:03|10000| Full | 60 | 0 | 600 | 600 | 1.07 | 17 10 35 | 2.0e+11 | | | 1.1e+11 | FCAL250 in beam, Full HV scan, EMEC bad 999 |14.04.2012|01:13|01:26|10000| Full | 0 | 0 | 0 | 0 | 1.07 | 17 10 35 | 2.0e+11 | | | 1.1e+11 | FCAL250 in beam, Full HV scan, EMEC bad 1000 |14.04.2012|01:40|01:53|10000| One | 0 | 100 | 1200 | 1200 | 1.07 | 17 10 9987 | 2.0e+11 | | | 1.1e+11 | FCAL100 in beam, One, EMEC bad 2012.04.14 02:10 Setting new intensity 1.0e+10, go to 1:10 (new for EMEC) attenuators and do full HV scan 1001 |14.04.2012|02:37|02:51|10000| Full | 250 | 0 | 1200 | 1200 | 1.25 | 17 10 35 | 1.1e+10 | | | 5.8e+9 | FCAL250 in beam, Full HV scan 1002 |14.04.2012|03:01|03:15|10000| Full | 160 | 0 | 800 | 800 | 1.25 | 17 10 35 | 1.1e+10 | | | 5.8e+9 | FCAL250 in beam, Full HV scan 1003 |14.04.2012|03:20|03:34|10000| Full | 60 | 0 | 600 | 600 | 1.25 | 17 10 35 | 1.1e+10 | | | 5.8e+9 | FCAL250 in beam, Full HV scan 1004 |14.04.2012|03:43|03:56|10000| Full | 0 | 0 | 0 | 0 | 1.25 | 17 10 35 | 1.1e+10 | | | 5.8e+9 | FCAL250 in beam, Full HV scan 2012.04.14 03:56 Setting new intensity 5.0e+9 and do full HV scan 1005 |14.04.2012|04:08|04:21|10000| Full | 0 | 0 | 0 | 0 | 1.35 | 17 10 35 | 5.1e+9 | | | 6.4e+9 | FCAL250 in beam, Full HV scan 1006 |14.04.2012|04:28|04:41|10000| Full | 60 | 0 | 600 | 600 | 1.35 | 17 10 35 | 5.1e+9 | | | 6.4e+9 | FCAL250 in beam, Full HV scan 1007 |14.04.2012|04:47|05:01|10000| Full | 160 | 0 | 800 | 800 | 1.35 | 17 10 35 | 5.1e+9 | | | 6.4e+9 | FCAL250 in beam, Full HV scan 1008 |14.04.2012|05:05|05:19|10000| Full | 250 | 0 | 1200 | 1200 | 1.35 | 17 10 35 | 5.1e+9 | | | 6.4e+9 | FCAL250 in beam, Full HV scan 05:15 Noticed that the program "Readout", reading the fast Cherenkov, seemed to be blocked (continuously writing "No spill"), the monitoring program "Display" was frozen from 03:56. Restarted "Readout" program after the run 1008. 2012.04.14 05:20 Setting new intensity 2.0e+9, go to 1:3 (new for EMEC) attenuators and do Mini HV scan 1009 |14.04.2012|05:52|06:05|10000| Mini | 250 | 0 | 1200 | 1200 | 1.46 | 17 10 35 | 2.4e+9 | | | 1.7e+9 | FCAL250 in beam, Mini HV scan 1010 |14.04.2012|06:12|06:25|10000| Mini | 60 | 0 | 600 | 600 | 1.46 | 17 10 35 | 2.4e+9 | | | 1.7e+9 | FCAL250 in beam, Mini HV scan 2012.04.14 06:30 Setting new intensity 1.0e+9 and do Full HV scan 1011 |14.04.2012|06:32|06:46|10000| Full | 60 | 0 | 600 | 600 | 1.56 | 17 10 35 | 9.1e+8 | | | 1.7e+9 | FCAL250 in beam, Full HV scan 1012 |14.04.2012|06:57|07:11|10000| Full | 160 | 0 | 800 | 800 | 1.56 | 17 10 35 | 9.1e+8 | | | 1.7e+9 | FCAL250 in beam, Full HV scan 1013 |14.04.2012|07:16|07:30|10000| Full | 250 | 0 | 1200 | 1200 | 1.56 | 17 10 35 | 9.1e+8 | | | 1.7e+9 | FCAL250 in beam, Full HV scan 1014 |14.04.2012|07:35|07:48|10000| Full | 250 | 0 | 1200 | 1200 | 1.56 | 17 10 35 | 9.1e+8 | | | 1.7e+9 | FCAL250 in beam, Full HV scan, repeat ... 1015 |14.04.2012|08:00|08:14|10000| Full | 0 | 0 | 0 | 0 | 1.56 | 17 10 35 | 9.1e+8 | | | 1.7e+9 | FCAL250 in beam, Full HV scan 1016 |14.04.2012|08:38|08:54|10000| One | 250 | 0 | 1200 | 1200 | 1.65 | 17 10 35 | 5.6e+8 | | | 5.0e+9 | FCAL250 in beam, One 1017 |14.04.2012|09:08|09:24|10000| One | 250 | 0 | 1200 | 1200 | 1.95 | 17 10 35 | 1.2e+8 | | | 3.6e+9 | FCAL250 in beam, One 1018 |14.04.2012|09:51|10:07|10000| One | 250 | 0 | 1200 | 1200 | 1.90 | 17 10 35 | 1.6e+8 | | | 5.2e+9 | FCAL250 in beam, One ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 2012.04.14 10:14 Change to lowest intensity, 5e6, and then install beam scintillators. Also install films to determine beam profile. Install Att=1:1 ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Run #| Date |Run |Run |Evts | Qua |HV_FCAL|HV_FCAL|HV_EMEC|HV_HEC|HV Cher| Position |Intensity from| S4 | S123 |Ionisation| Comments | |start|stop | | lity |250[kV]|100[kV]| [kV] | [kV] | [kV] |HEC EMEC FCal| Cerenkov | | | chamber | | |time |time | | | | | | | | | | | | | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 1019 |14.04.2012|11:15|11:31|10000| One | 250 | 0 | 1200 | 1200 | 2.50 | 17 10 35 | 4.e+6 | ~40 | ~400000| | FCAL250 in beam, One 2012.04.14 11:40 HV on beam counters was changed. 1020 |14.04.2012|11:46|12:03|10000| One | 250 | 0 | 1200 | 1200 | 2.50 | 17 10 35 | 4.e+6 | ~300 | ~1e6 | | FCAL250 in beam, One 1021 |14.04.2012|12:21|12:54|20000| One | 250 | 0 | 1200 | 1200 | 2.50 | 17 10 35 | 4.e+6 | ~300 | ~1e6 | | FCAL250 in beam, One 1022 |14.04.2012|13:20|13:52|20000| One | 0 | 100 | 1200 | 1200 | 2.50 | 17 10 9987 | 4.e+6 | ~300 | ~1e6 | | FCAL100 in beam, One 1023 |14.04.2012|14:01|14:33|20000| One | 0 | 100 | 1200 | 1200 | 2.50 | 17 10 9987 | 5.e+6 | ~270 | ~1e6 | | FCAL100 in beam, One new intensity 1e7 1024 |14.04.2012|14:53|15:26|20000| Mini | 0 | 100 | 1200 | 1200 | 2.50 | 17 10 9987 | 1.0+7 | ~600 | ~1e6 | | FCAL100 in beam, Mini scan 1025 |14.04.2012|15:37|16:12|20000| Mini | 0 | 100 | 1200 | 1200 | 2.50 | 17 10 9987 | 0,6-1,2e+7 | ~600 | ~1e6 | | FCAL100 in beam, Mini scan 1026 |14.04.2012|16:26|16:58|20000| Mini | 0 | 40 | 500 | 500 | 2.50 | 17 10 9987 | 1.0e+7 | ~450 | ~1e6 | | FCAL100 in beam, Mini scan 1027 |14.04.2012|17:25|17:29| 2000| test | 0 | 100 | 1200 | 1200 | 2.50 | 17 10 9987 | 1.0e+7 | ~450 | ~1e6 | | check small signals in FCAL+HEC 1028 |14.04.2012|18:08|18:40|20000| Mini | 0 | 100 | 1200 | 1200 | 2.50 | 17 10 9987 | 1.0e+7 | ~450 | ~1e6 | | FCAL100 in beam, Mini scan 1029 |14.04.2012|19:05|19:38|20000| Mini | 0 | 40 | 500 | 500 | 2.50 | 17 10 9987 | 1.0e+7 | ~1000 | ~1e6 | | FCAL100 in beam, Mini scan 1030 |14.04.2012| | |20000| Mini | 60 | 0 | 600 | 600 | 2.50 | 17 10 35 | 1.0e+7 | ~450 | ~1e6 | | canceled run, not properly terminated, analysis crashes 1031 |14.04.2012|19:53|20:26|20000| Mini | 60 | 0 | 600 | 600 | 2.50 | 17 10 35 | 1.0e+7 | ~450 | ~1e6 | | FCAL250 in beam, Mini scan 1032 |14.04.2012|21:27|22:00|20000| Mini | 60 | 0 | 600 | 600 | 2.50 | 17 10 35 | 1.0e+7 | ~550 | ~1e6 | | FCAL250 in beam, Mini scan 1033 |14.04.2012|22:07|22:40|20000| Mini | 250 | 0 | 1200 | 1200 | 2.50 | 17 10 35 | 1.0e+7 | ~550 | ~1e6 | | FCAL250 in beam, Mini scan 1034 |14.04.2012|22:47|23:03| 8000| Mini | 250 | 0 | 1200 | 1200 | 2.50 | 17 10 35 | 1.0e+7 | ~550 | ~1e6 | | FCAL250 in beam, Mini scan, run stopped, no beam 1035 |15.04.2012|01:20|01:57|20000| Mini | 250 | 0 | 1200 | 1200 | 2.50 | 17 10 35 | 8.0e+6 | ~609 | 1.2e6 | | FCAL250 in beam, Mini scan, run 1034 re-take new intensity 2e7 1036 |15.04.2012|02:05|02:38|20000| Mini | 250 | 0 | 1200 | 1200 | 2.50 | 17 10 35 | 1.6e+7 | ~450 | 1.1e6 | | FCAL250 in beam, Mini scan, 1037 |15.04.2012|03:11|03:47|20000| Mini | 60 | 0 | 600 | 600 | 2.10 | 17 10 35 | (2-3)e+7 | ~1400| 1.2e6 | | FCAL250 in beam, Mini scan, 1038 |15.04.2012|03:58|04:30|20000| Mini | 0 | 40 | 500 | 500 | 2.10 | 17 10 9987 | (1-3)e+7 | ~1000| 1.1e6 | | FCAL100 in beam, Mini scan, 1039 |15.04.2012|04:39|05:04|15244| Mini | 0 | 100 | 1000 | 1000 | 2.10 | 17 10 9987 | (0.5-2.5)e+7| ~1000| 1.1e6 | | FCAL100 in beam, Mini scan, run stopped due to intensity fluctuation 1040 |15.04.2012|05:15|05:48|20000| Mini | 0 | 100 | 1000 | 1000 | 2.10 | 17 10 9987 | (1.5-2.5)e+7| ~1000| 1.1e6 | | FCAL100 in beam, Mini scan, new intensity 5e7 1041 |15.04.2012|06:01|06:34|20000| One | 0 | 100 | 1000 | 1000 | 1.95 | 17 10 9987 | (~4.5-5.5)e+7| ~3000| 1.1e6 | | FCAL100 in beam, One, but HV=1000! 1042 |15.04.2012|10:50|11:00| 2000| test| 250 | 0 | 1200 | 1200 | 1.95 | 17 10 35 | | | | | noise test run without beam 1043 |15.04.2012|12:17| | 1000| test| 250 | 0 | 1200 | 1200 | 1.95 | 17 10 35 | 3.e+6 | | | | noise test run with beam 1044 |15.04.2012|12:22| | 1000| test| 250 | 0 | 1200 | 1200 | 1.95 | 17 10 35 | | | | | noise test run with beam with sc cables unplugged 1045 |15.04.2012|12:28| | 1000| test| 250 | 0 | 1200 | 1200 | 1.95 | 17 10 35 | | | | | noise test run no HV on counters 1046 |15.04.2012|12:38|13:11|20000| One | 250 | 0 | 1200 | 1200 | 2.20 | 17 10 35 | 5.8e+7 | ~400 | 1.3e+6 | | FCAL250 in beam, One 1047 |15.04.2012|13:15|13:20| 100| test | 250 | 0 | 1200 | 1200 | 2.20 | 17 10 35 | 5.8e+7 | ~400 | 1.3e+6 | | FCAL250 in beam, test with no beam .... 1048 |15.04.2012|13:35|13:41| 1000| One | 250 | 0 | 1200 | 1200 | 2.12 | 17 10 35 | 5.8e+7 | ~400 | 1.3e+6 | | FCAL250 in beam, test, Hodoscope connected to table! 1049 |15.04.2012|14:08|14:13| 1000| One | 250 | 0 | 1200 | 1200 | 2.12 | 17 10 35 | 5.8e+7 | ~400 | 1.3e+6 | | FCAL250 in beam, test, Hodoscope out 1050 |15.04.2012|14:35|14:36| 1000| One | 250 | 0 | 1200 | 1200 | 2.12 | 17 10 35 | 5.8e+7 | ~400 | 1.3e+6 | | FCAL250 in beam, test, Hodoscope out, unplug cal.cables 14:45 new intensity 2e+11, install attenuators 1:30 16:00 repeating runs 996,997,.. now with EMEC attenuators ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Run #| Date |Run |Run |Evts | Qua |HV_FCAL|HV_FCAL|HV_EMEC|HV_HEC|HV Cher| Position |Intensity from| S4 | S123 |Ionisation| Comments | |start|stop | | lity |250[kV]|100[kV]| [kV] | [kV] | [kV] |HEC EMEC FCal| Cerenkov | | | chamber | | |time |time | | | | | | | | | | | | | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 1051 |15.04.2012|15:45|16:12|20000| Full | 250 | 0 | 1200 | 1200 | 1.05 | 17 10 35 | 1.9e+11 | | | 1.2e+11 | FCAL250 in beam, Full HV scan 1052 |15.04.2012|16:31|17:04|20000| Full | 160 | 0 | 800 | 800 | 1.05 | 17 10 35 | 1.7e+11 | | | | FCAL250 in beam, Full HV scan: intensity fluctuating 1053 |15.04.2012|18:05|18:25| 5600|abort | 60 | 0 | 600 | 600 | 1.05 | 17 10 35 | 1.7e+11 | | | | FCAL250 in beam, Full HV scan: aborted, no beam again 1054 |15.04.2012|20:11|20:34| 3800|abort | 60 | 0 | 600 | 600 | 1.05 | 17 10 35 | 1.7e+11 | | | 1.6e+11 | FCAL250 in beam, Full HV scan: aborted again no beam 1055 |15.04.2012|20:39|21:07|20000| Full | 60 | 0 | 600 | 600 | 1.05 | 17 10 35 | 1.6e+11 | | | 1.1e+11 | FCAL250 in beam, Full HV scan finally good 1056 |15.04.2012|21:14|21:41|20000| Full | 0 | 0 | 0 | 0 | 1.05 | 17 10 35 | 1.6e+11 | | | 3.1e+10 | FCAL250 in beam, Full HV scan intens down to 1.0e+11 1057 |15.04.2012|21:53|21:09|20000| Full | 0 | 40 | 500 | 500 | 1.05 | 17 10 9987 | 1.0e+11 | | | | FCAL100 in beam, Full HV scan intens fluctuating 8.e10 -> 1.8e11 1058 |15.04.2012|22:27|22:54|20000| Full | 0 | 60 | 700 | 700 | 1.05 | 17 10 9987 | 1.5e+11 | | | 1.0e+11 | FCAL100 in beam, Full HV scan 1059 |15.04.2012|23:01|23:29|20000| Full | 0 | 100 | 1000 | 1000 | 1.05 | 17 10 9987 | 1.6e+11 | | | | FCAL100 in beam, Full HV scan 23:30 new intensity 1.0e+11, Fcal100 is in 1060 |15.04.2012|23:37|00:05|20000| Mini | 0 | 100 | 1000 | 1000 | 1.05 | 17 10 9987 | 1.2e+11 | | | | FCAL100 in beam, Full HV scan 1061 |16.04.2012|00:13|00:41|20000| Mini | 0 | 40 | 500 | 500 | 1.06 | 17 10 9987 | 1.2e+11 | | | | FCAL100 in beam, Full HV scan 1062 |16.04.2012|00:50|01:17|20000| Full | 60 | 0 | 600 | 600 | 1.06 | 17 10 35 | 1.2e+11 | | | | FCAL250 in beam, Mini HV scan 1063 |16.04.2012|01:32|01:59|20000| Full | 250 | 0 | 1200 | 1200 | 1.06 | 17 10 35 | 1.1e+11 | | | | FCAL250 in beam, Mini HV scan 1064 |16.04.2012|02:21|02:49|20000| Full | 160 | 0 | 800 | 800 | 1.06 | 17 10 35 | 1.1e+11 | | | | FCAL250 in beam, Mini HV scan EMEC ch#2 dead ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Run #| Date |Run |Run |Evts | Qua |HV_FCAL|HV_FCAL|HV_EMEC|HV_HEC|HV Cher| Position |Intensity from| S4 | S123 |Ionisation| Comments | |start|stop | | lity |250[kV]|100[kV]| [kV] | [kV] | [kV] |HEC EMEC FCal| Cerenkov | | | chamber | | |time |time | | | | | | | | | | | | | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 2x10^8 attenuators 1:1 1065 |16.04.2012|04:11|04:38|20000| Full | 250 | 0 | 1200 | 1200 | 1.80 | 17 10 35 | 2.8e+8 | | | | FCAL250 in beam, first ~1/2 of run Ic=7.0e+8 EMEC discharges on Drezden monior... 1066 |16.04.2012|04:49|05:18|20000| Full | 160 | 0 | 800 | 800 | 1.80 | 17 10 35 | 3.1e+8 | | | | FCAL250 in beam, some data at 6x10^7 1067 |16.04.2012|05:24|05:36| 8875| Full | 60 | 0 | 600 | 600 | 2.00 | 17 10 35 | 3.1e+8 | | | | FCAL250 in beam, stop due vacuum problem